Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Infection Control ; (4): 930-933, 2016.
Article in Chinese | WPRIM | ID: wpr-508569

ABSTRACT

Objective To study the occurrence,risk factors,and direct economic losses caused by healthcare-asso-ciated infection(HAI)in hemodialysis patients in a hospital.Methods 840 patients who underwent hemodialysis in this hospital from April 2012 to September 2014 were selected,incidence of HAI,related factors,and economic los-ses due to HAI were investigated.Results Among 840 hemodialysis patients,89 patients developed 104 times of HAI,HAI density was 4.27‰ . Multivariate regression analysis showed that young age and old age,combined mul-tiple diseases,long duration of hemodialysis,two or more intubation sites,prolonged intubation,long length of hospital stay were all risk factors for HAI(OR= 1.123-2.325);Fees for bed,consultation,examination,treat-ment,nursing,medicine,and others in HAI group were all significantly higher than non-infected group(H= 49.6-1 038.9,all P<0.01 ),difference in medicine fees was most significant.Conclusion Risk factors for HAI are young age and old age,combined multiple diseases,long duration of hemodialysis,two or more intubation sites, prolonged intubation,and long length of hospital stay,the occurrence of HAI can increase the economic burden of hemodialysis patients.

2.
Chinese Journal of Nosocomiology ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-588636

ABSTRACT

OBJECTIVE To know the disinfection efficacy of electrolyzed oxidizing water(EOW) and glutaraldehyde on clinical used gastroscope and enteroscope in our hospital and to analyze their stability and probable harm.METHODS The gastroscope and enteroscope before and after use on randomly selected outpatients and inpatients were examined on their contamination,and the efficacy of EOW was compared with that of glutaraldehyde.RESULTS After using EOW and glutaraldehyde to disinfect the gastroscope and enteroscope the former showed that its killing rate on commonly encountered pathogens for 1 min was 93.75-98.22%,for 3 min was 81.20-89.29%,and for 5 min was 100.00%;the latter showed that its killing rate for 3 min was 81.20-89.29%,for 5 min was 90.38-93.04%,and for 10 min was 99.92-99.96%.EOW was non-irritative to mucosa,and didn′t cause allergic reaction,but its stability was poor.The glutaraldehyle could bring some side effects,such as some allergy,and mucosa stimulation.CONCLUSIONS It only needs 3-5 min for EOW to kill polluted bacteria on gastroscope and enteroscope to attain the disinfection eligibility,but glutaraldehyde needs more than 10 min to get to the disinfection eligibility.The effect of EOW is strong,rapid,active and environment-safe,it is worthy of application,but it must be applied immediately as soon as possible after production.The use of glutaraldehyde must strengthen the measures of personal protection.

3.
Chinese Journal of Nosocomiology ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-588816

ABSTRACT

OBJECTIVE To study the bactericidal efficacy of glutaraldehyde,and its stability and change in pH value.METHODS The carrier quantity bactericidal test,field mimic bactericidal test,stability test,pH value detection,periodical biological surveillance and follow-up investigation of hospital infection were used.RESULTS After using of 20 000 mg/L of neutral glutaraldehyde on Candida albicans(ATCC 10231),Pseudomonas aeruginosa(ATCC27853),Escherichia coli(ATCC 25922) and other 3 clinical isolates separately for 3,5,and 10 min,the average killing rate was 97.90%,99.83% and 100.00%;on the field mimic bactericidal test with MRSA contaminated gastroscope,the average killing rate was 87.84%,99.50%,and 100.00%,respectively.The concentration of disinfectant after storaging 14d on 54℃ was decreased,only loss 1.46%,the concentration loss of disinfectant on using endoscope 5,7,and 14d after disinfection was 2.64%,0.69% and 0.94%,respectively.The value of pH was decreased from 7.22 to 6.00,6.50,and 6.20.The qualification rate of 260 various endoscopes after surveillance was 100.00%.Their was one of hospital infection happened among 3 200 patients after endoscopy which were followed up.CONCLUSIONS The results show that,only under the following circumstances,namely the concentration of glutaraldehyde being no less than 20 000mg/L and the action time being no less than 10 min,timely alteration of glutaraldehyde,and regular biological and concentration monitoring could the disinfection of endoscope be qualified so that hospital infection can be prevented,and medical dispute may be put to an end.

SELECTION OF CITATIONS
SEARCH DETAIL